please dont rip this site

This section is implemented as a multilevel document. This page serves as an executive summary of the 1284 standard. By clicking on the various highlighted points, you may explore each concept in greater detail.


Introduction to the IEEE 1284-1994 Standard

The recently released standard, "IEEE Std.1284-1994 Standard Signaling Method for a Bi-directional Parallel Peripheral Interface for Personal Computers", is for the parallel port what the Pentium processor is to the 286. The standard provides for high speed bi-directional communiction between the PC and an external peripheral that can communicate 50 to 100 times faster that the original parallel port. It can do this and still be fully backward compatible with all existing parallel port peripherals and printers.

The 1284 standard defines 5 modes of data transfer. Each mode provides a method of transfering data in either the forward direction (PC to peripheral), reverse direction (peripheral to PC) or bi-directional data transfer (half duplex). The defined modes are:

All parallel ports can implement a bi-directional link by using the Compatible and Nibble modes for data transfer. Byte mode can be utilized by about 25% of the installed base of parallel ports. All three of these modes utilize software only to transfer the data. The driver has to write the data, check the handshake lines (ie: BUSY), assert the appropriate control signals (ie: STROBE) and then go on to the next byte. This is very software intensive and limits the effective data transfer rate to 50 to 100 Kbytes per second.

In addition to the previous 3 modes, EPP and ECP are being implemented on the latest I/O controllers by most of the Super I/O chip manufacturers. These modes use hardware to assist in the data transfer. For example, in EPP mode, a byte of data can be transfered to the peripheral by a simple OUT instruction. The I/O controller handles all the handshaking and data transfer to the peripheral.

Overall, the 1284 standard provides the following:

  1. 5 modes of operation for data transfer
  2. A method for the host and peripheral to determine the supported modes and to negotiate to the requested mode.
  3. Defines the physical interface
  4. Defines the electrical interface

In summary, the 1284 parallel port provides an easy to use, high performace interface for portable products and printers.

See:


file: /Techref/io/parallel/1284/1284int.htm, 3KB, , updated: 2002/2/14 16:23, local time: 2024/12/26 17:55,
TOP NEW HELP FIND: 
3.145.196.141:LOG IN

 ©2024 These pages are served without commercial sponsorship. (No popup ads, etc...).Bandwidth abuse increases hosting cost forcing sponsorship or shutdown. This server aggressively defends against automated copying for any reason including offline viewing, duplication, etc... Please respect this requirement and DO NOT RIP THIS SITE. Questions?
Please DO link to this page! Digg it! / MAKE!

<A HREF="http://techref.massmind.org/Techref/io/parallel/1284/1284int.htm"> IEEE 1284 Introduction</A>

After you find an appropriate page, you are invited to your to this massmind site! (posts will be visible only to you before review) Just type a nice message (short messages are blocked as spam) in the box and press the Post button. (HTML welcomed, but not the <A tag: Instead, use the link box to link to another page. A tutorial is available Members can login to post directly, become page editors, and be credited for their posts.


Link? Put it here: 
if you want a response, please enter your email address: 
Attn spammers: All posts are reviewed before being made visible to anyone other than the poster.
Did you find what you needed?

 

Welcome to massmind.org!

 

Welcome to techref.massmind.org!

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

  .